{"id":1714,"date":"2025-10-30T10:35:24","date_gmt":"2025-10-30T09:35:24","guid":{"rendered":"https:\/\/www.ofenfeinstaubfilter.de\/service\/installation\/"},"modified":"2026-01-16T12:55:50","modified_gmt":"2026-01-16T11:55:50","slug":"installation","status":"publish","type":"page","link":"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/","title":{"rendered":"Installation"},"content":{"rendered":"<div class=\"wpb-content-wrapper\" id=\"wpb-content-root\"><p>[vc_row el_class=&#8221;padding-container background-ornament-hero&#8221;][vc_column]\n<section class=\"hero-subpage-section-wrapper \">\n    <div class=\"hero-subpage-section-left\n                         col-12\n            \">\n                    <h1 class=\"hero-headline\">Installation<\/h1>\n                \n            <\/div>\n\n\n    <\/section>[\/vc_column][\/vc_row][vc_row el_class=&#8221;c_container&#8221;][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<h2>Preparation for Installation<\/h2>\n<p>Proper installation of the furnace dust filter is crucial for its optimal function and your safety. Whether you are installing the filter for your customers or retrofitting it in your own home as a private individual, careful preparation is important in either case. Take enough time for planning to avoid complications later on.<\/p>\n<h3>Required Preliminary Checks:<\/h3>\n<ul>\n<li aria-level=\"1\">Checking that the fireplace is in perfect condition<\/li>\n<li aria-level=\"1\">Confirmation that the system is suitable for retrofitting<\/li>\n<li aria-level=\"1\">Combustion calculation by the chimney sweep<\/li>\n<li aria-level=\"1\">Checking the accessibility of the exhaust system<\/li>\n<\/ul>\n<p>Particularly for private use in your own home, installation should always be carried out in consultation with the responsible chimney sweep. They will not only check the technical suitability, but also carry out the necessary calculations, as the fine dust filter slightly increases the pressure loss in the system. This is particularly relevant during the heating phase, when the necessary negative pressure in the chimney has not yet been fully established.<\/p>\n<p>This ensures that your oven fine dust filter works efficiently and complies with legal requirements \u2013 both in your own home and in professional use by specialist companies.[\/vc_column_text][\/vc_column][\/vc_row][vc_row el_class=&#8221;padding-container background-alt pt-4&#8243;][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<h2>Installation of the Catalytic Converter Unit<\/h2>\n<p>The catalytic converter unit is the technical heart of the filter system. It consists of two sponge ceramic catalytic converters with a special precious metal coating and is pre-installed in the flue pipe at the factory.<\/p>\n<p>Important handling rules:<\/p>\n<ul>\n<li aria-level=\"1\">Always wear protective gloves.<\/li>\n<li aria-level=\"1\">Never touch catalysts with your bare hands.<\/li>\n<li aria-level=\"1\">Handle the coating with care<\/li>\n<li aria-level=\"1\">Use optical positioning aids for correct alignment<\/li>\n<\/ul>\n<p>The catalyst is relatively insensitive due to the fact that the coating forms a spinel with the substrate. Nevertheless, careful handling is recommended.<\/p>\n<h3>Installation in the Flue Gas Piping<\/h3>\n<p>[\/vc_column_text]\n<div class=\"product-expandable-sections \">\n    <div class=\"container\">\n        <div class=\"expandable-sections\">\n            <div class=\"expandable-section\">\n                <button class=\"section-header\" data-section=\"vc-accordion-67036000\">\n                    <span>Step 1: Preparing the installation area<\/span>\n                    <svg class=\"arrow\"><use href=\"#chevron-down\"><\/use><\/svg>\n                <\/button>\n                <div class=\"section-content\" id=\"vc-accordion-67036000\">\n                    <div class=\"section-content-inner\">\n                    A precisely measured section must be removed from the existing flue gas piping. The flue pipe of the furnace fine dust filter has a total length of 300 mm with a 50 mm recess.<\/p>\n<p>Calculation:<\/p>\n<ul>\n<li>Total pipe length: 300 mm<\/li>\n<li>Recess: 50 mm<\/li>\n<li>Pipe section to be removed: 250 mm<\/li>\n<\/ul>\n<p>Cover the work area with a tarpaulin and have all tools ready. The cut surfaces must be clean and free of burrs for optimum sealing later on.                    <\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<div class=\"product-expandable-sections \">\n    <div class=\"container\">\n        <div class=\"expandable-sections\">\n            <div class=\"expandable-section\">\n                <button class=\"section-header\" data-section=\"vc-accordion-8087860\">\n                    <span>Step 2: Selecting the installation position<\/span>\n                    <svg class=\"arrow\"><use href=\"#chevron-down\"><\/use><\/svg>\n                <\/button>\n                <div class=\"section-content\" id=\"vc-accordion-8087860\">\n                    <div class=\"section-content-inner\">\n                    The furnace dust filter offers flexible installation options:<\/p>\n<p>Vertical installation (recommended)<\/p>\n<ul>\n<li>Best air flow<\/li>\n<li>Minimal dust deposits<\/li>\n<li>Gravity assists particle removal<\/li>\n<\/ul>\n<p>Inclined installation<\/p>\n<ul>\n<li>Service flap\/bypass aligned upwards<\/li>\n<li>Service flap must remain easily accessible<\/li>\n<li>Protect bypass area from deposits<\/li>\n<\/ul>\n<p>Horizontal installation (special care)<\/p>\n<ul>\n<li>Service flap \/ bypass facing upwards<\/li>\n<li>Bypass also positioned at the top<\/li>\n<li>More frequent checks required<\/li>\n<\/ul>\n<p>                    <\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<div class=\"product-expandable-sections \">\n    <div class=\"container\">\n        <div class=\"expandable-sections\">\n            <div class=\"expandable-section\">\n                <button class=\"section-header\" data-section=\"vc-accordion-97100418\">\n                    <span>Step 3: Making the connections<\/span>\n                    <svg class=\"arrow\"><use href=\"#chevron-down\"><\/use><\/svg>\n                <\/button>\n                <div class=\"section-content\" id=\"vc-accordion-97100418\">\n                    <div class=\"section-content-inner\">\n                    The connection is made using the tried-and-tested plug-in principle, whereby the wide end of the filter pipe is plugged onto the tapered exhaust pipe. This design not only enables a secure mechanical connection, but also makes subsequent maintenance work considerably easier.<\/p>\n<p>Sealing the connection points:<\/p>\n<ul>\n<li>Check all plug connections<\/li>\n<li>Use approved heat-resistant sealants<\/li>\n<li>Ensure that the sealant is applied evenly<\/li>\n<li>Remove any excess material<\/li>\n<\/ul>\n<p>                    <\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n[vc_column_text css=&#8221;&#8221;]<\/p>\n<h3>Important Assembly Instructions<\/h3>\n<p><b>Diameter compatibility<\/b><\/p>\n<p>The filter is designed for flue pipes with an internal diameter of 150 mm as standard. The following rules apply for different diameters:[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]<strong>Smaller diameters:<\/strong><\/p>\n<ul>\n<li aria-level=\"1\">Expandable with adapters<\/li>\n<li aria-level=\"1\">Expansion always in the direction of flow<\/li>\n<li aria-level=\"1\">Avoid turbulence<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]<strong>Larger diameters:<\/strong><\/p>\n<ul>\n<li aria-level=\"1\">Not compatible with this model<\/li>\n<li aria-level=\"1\">Alternative solutions required<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<h3>The Bypass Function<\/h3>\n<p>The integrated bypass is a critical safety element of the system. It ensures that exhaust gases can be safely discharged even if the filter unit is partially blocked. Correct positioning and regular inspection of the bypass are therefore of utmost importance.<\/p>\n<p>Checkpoints for the bypass:<\/p>\n<ul>\n<li aria-level=\"1\">Check free flowability before each start-up<\/li>\n<li aria-level=\"1\">No deposits in the bypass area<\/li>\n<li aria-level=\"1\">For horizontal installation: bypass positioned at the top<\/li>\n<li aria-level=\"1\">Regular visual inspection through service hatch<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>Safety Distances<\/h3>\n<p>Maintaining safe distances is required by law and is non-negotiable:<\/p>\n<p>Minimum distances from combustible materials:<\/p>\n<ul>\n<li aria-level=\"1\">500 mm in all heat-radiating directions<\/li>\n<li aria-level=\"1\">For vertical installation: front, rear, left and right<\/li>\n<li aria-level=\"1\">For horizontal installation: upwards, downwards and to both sides<\/li>\n<\/ul>\n<p>Wall penetrations must comply with applicable building regulations and fire safety regulations. The expertise of your chimney sweep is essential here.[\/vc_column_text][\/vc_column][\/vc_row][vc_row el_class=&#8221;c_container&#8221;][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<h2>After Installation<\/h2>\n<p>[\/vc_column_text][\/vc_column][vc_column offset=&#8221;vc_col-lg-6&#8243;][vc_column_text css=&#8221;&#8221;]<\/p>\n<h3>Commissioning Checklist<\/h3>\n<p>After completing the installation work, you should systematically check the following points:<\/p>\n<p>Before initial commissioning:<\/p>\n<ul>\n<li aria-level=\"1\">Check all connections for leaks.<\/li>\n<li aria-level=\"1\">Verify the correct position of all seals.<\/li>\n<li aria-level=\"1\">Check that the clamp connections are secure<\/li>\n<li aria-level=\"1\">Service flap completely closed<\/li>\n<li aria-level=\"1\">Catalyst and bypass freely flowable<\/li>\n<li aria-level=\"1\">Safety distances maintained<\/li>\n<\/ul>\n<p>When firing up for the first time, heat moderately at first and observe the system closely. The catalytic converter requires a minimum temperature of 200\u00b0C to be fully effective \u2013 this temperature is easily reached during normal operation.[\/vc_column_text][\/vc_column][vc_column offset=&#8221;vc_col-lg-6&#8243;][vc_column_text css=&#8221;&#8221;]<\/p>\n<h3>Special Notes for Retrofitting<\/h3>\n<p>Special conditions must be observed when retrofitting existing wood-burning stoves. The stove fine dust filter was developed specifically for retrofitting, but is subject to technical limitations.<\/p>\n<p>Technical requirements:<\/p>\n<ul>\n<li aria-level=\"1\">Nominal heat output: 5\u201312 kW<\/li>\n<li aria-level=\"1\">Only simply blocked chimneys<\/li>\n<li aria-level=\"1\">Exhaust gas temperature: 200\u2013500\u00b0C<\/li>\n<li aria-level=\"1\">Pipe diameter: 150 mm (or adaptable)<\/li>\n<\/ul>\n<p>The performance limitation is technically justified. If the systems are too small, the exhaust gas temperature may not be sufficient to activate the catalytic converter. If the systems are too large, the exhaust gas volume could exceed the filter capacity and lead to operational malfunctions.[\/vc_column_text][\/vc_column][vc_column offset=&#8221;vc_hidden-lg vc_hidden-md vc_hidden-sm vc_hidden-xs&#8221;][vc_column_text css=&#8221;&#8221;]<\/p>\n<h3>Documentation and Official Approval<\/h3>\n<p>The proper installation must be approved by a chimney sweep and documented in a report. The chimney sweep must perform a chimney calculation in advance. This approval not only serves formal requirements, but is also an important component of your legal protection.<\/p>\n<p>Documents to be retained:<\/p>\n<ul>\n<li aria-level=\"1\">Installation instructions<\/li>\n<li aria-level=\"1\">Chimney sweep&#8217;s inspection report<\/li>\n<li aria-level=\"1\">Proof of purchase and warranty documents<\/li>\n<li aria-level=\"1\">Maintenance records<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row el_class=&#8221;padding-container background-alt pt-4&#8243;][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<h2>Avoid Common Installation Errors<\/h2>\n<p>Practical experience has revealed typical sources of error that you should avoid:<\/p>\n<p><b>The most common mistakes:<\/b><\/p>\n<ul>\n<li aria-level=\"1\">Inadequate sealing of the joints<\/li>\n<li aria-level=\"1\">Incorrect positioning during horizontal installation<\/li>\n<li aria-level=\"1\">Neglecting bypass control<\/li>\n<li aria-level=\"1\">Failure to maintain safety distances<\/li>\n<li aria-level=\"1\">Installation without prior chimney sweep inspection<\/li>\n<\/ul>\n<p>Troubleshooting during installation<\/p>\n<p>If you encounter any problems during installation, the following solutions may help:[\/vc_column_text][\/vc_column][\/vc_row][vc_row el_class=&#8221;c_container&#8221;][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<h2>Final Recommendations<\/h2>\n<p>Installing a fine dust filter for your furnace is an important investment in environmental protection and health. Careful, professional installation is the basis for years of reliable operation. Take the time necessary for installation and do not hesitate to seek professional help if you are unsure.<\/p>\n<p><b>Our service for you:<\/b><\/p>\n<ul>\n<li aria-level=\"1\">Technical support for installation questions<\/li>\n<li aria-level=\"1\">Detailed documentation<\/li>\n<li aria-level=\"1\">Qualified specialist partners in your region<\/li>\n<li aria-level=\"1\">Original spare parts and accessories<\/li>\n<\/ul>\n<p>If you have any technical questions or uncertainties during installation, our support team will be happy to assist you. We will help you to install your furnace dust filter optimally and put it into operation.[\/vc_column_text]\n<div class=\"product-expandable-sections \">\n    <div class=\"container\">\n        <div class=\"expandable-sections\">\n            <div class=\"expandable-section\">\n                <button class=\"section-header\" data-section=\"20\">\n                    <span>Problem: Pipe diameters do not match<\/span>\n                    <svg class=\"arrow\"><use href=\"#chevron-down\"><\/use><\/svg>\n                <\/button>\n                <div class=\"section-content\" id=\"20\">\n                    <div class=\"section-content-inner\">\n                    <\/p>\n<ul>\n<li>Solution: Use suitable adapters<\/li>\n<li>Always widen in the direction of flow<\/li>\n<\/ul>\n<p>                    <\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<div class=\"product-expandable-sections \">\n    <div class=\"container\">\n        <div class=\"expandable-sections\">\n            <div class=\"expandable-section\">\n                <button class=\"section-header\" data-section=\"21\">\n                    <span>Problem: Service flap not accessible<\/span>\n                    <svg class=\"arrow\"><use href=\"#chevron-down\"><\/use><\/svg>\n                <\/button>\n                <div class=\"section-content\" id=\"21\">\n                    <div class=\"section-content-inner\">\n                    <\/p>\n<ul>\n<li>Solution: Insert spacer<\/li>\n<li>Check alternative position<\/li>\n<\/ul>\n<p>                    <\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n\n<div class=\"product-expandable-sections \">\n    <div class=\"container\">\n        <div class=\"expandable-sections\">\n            <div class=\"expandable-section\">\n                <button class=\"section-header\" data-section=\"22\">\n                    <span>Problem: Insufficient space for safety distances<\/span>\n                    <svg class=\"arrow\"><use href=\"#chevron-down\"><\/use><\/svg>\n                <\/button>\n                <div class=\"section-content\" id=\"22\">\n                    <div class=\"section-content-inner\">\n                    <\/p>\n<ul>\n<li>Solution: Select an alternative installation position<\/li>\n<li>Discuss fire safety measures with a chimney sweep<\/li>\n<\/ul>\n<p>                    <\/div>\n                <\/div>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/div>\n[\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Preparation for Installation Proper installation of the furnace dust filter is crucial for its optimal function and your safety. Whether you are installing the filter for your customers or retrofitting it in your own home as a private individual, careful&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1696,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-1714","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Installation | Ofenfeinstaubfilter<\/title>\n<meta name=\"description\" content=\"Installing the stove fine dust filter: required checks, tools needed and a step-by-step guide for professional fitters and private retrofitting.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Installation | Ofenfeinstaubfilter\" \/>\n<meta property=\"og:description\" content=\"Installing the stove fine dust filter: required checks, tools needed and a step-by-step guide for professional fitters and private retrofitting.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/\" \/>\n<meta property=\"og:site_name\" content=\"OFENFEINSTAUBFILTER\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-16T11:55:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.ofenfeinstaubfilter.de\/wp-content\/uploads\/2025\/10\/Filter_Teaser.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"517\" \/>\n\t<meta property=\"og:image:height\" content=\"624\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/service\\\/installation\\\/\",\"url\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/service\\\/installation\\\/\",\"name\":\"Installation | Ofenfeinstaubfilter\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/#website\"},\"datePublished\":\"2025-10-30T09:35:24+00:00\",\"dateModified\":\"2026-01-16T11:55:50+00:00\",\"description\":\"Installing the stove fine dust filter: required checks, tools needed and a step-by-step guide for professional fitters and private retrofitting.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/service\\\/installation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/service\\\/installation\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/service\\\/installation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Service\",\"item\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/service\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Installation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/\",\"name\":\"OFENFEINSTAUBFILTER\",\"description\":\"by BERTRAMS + BLUEFIRE + CULIMETA\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/#organization\",\"name\":\"OFENFEINSTAUBFILTER\",\"url\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/Ofenfeinstaubfilter_Logo_blau.webp\",\"contentUrl\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/Ofenfeinstaubfilter_Logo_blau.webp\",\"width\":1920,\"height\":308,\"caption\":\"OFENFEINSTAUBFILTER\"},\"image\":{\"@id\":\"https:\\\/\\\/www.ofenfeinstaubfilter.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Installation | Ofenfeinstaubfilter","description":"Installing the stove fine dust filter: required checks, tools needed and a step-by-step guide for professional fitters and private retrofitting.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/","og_locale":"en_US","og_type":"article","og_title":"Installation | Ofenfeinstaubfilter","og_description":"Installing the stove fine dust filter: required checks, tools needed and a step-by-step guide for professional fitters and private retrofitting.","og_url":"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/","og_site_name":"OFENFEINSTAUBFILTER","article_modified_time":"2026-01-16T11:55:50+00:00","og_image":[{"width":517,"height":624,"url":"https:\/\/www.ofenfeinstaubfilter.de\/wp-content\/uploads\/2025\/10\/Filter_Teaser.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/","url":"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/","name":"Installation | Ofenfeinstaubfilter","isPartOf":{"@id":"https:\/\/www.ofenfeinstaubfilter.de\/en\/#website"},"datePublished":"2025-10-30T09:35:24+00:00","dateModified":"2026-01-16T11:55:50+00:00","description":"Installing the stove fine dust filter: required checks, tools needed and a step-by-step guide for professional fitters and private retrofitting.","breadcrumb":{"@id":"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/installation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.ofenfeinstaubfilter.de\/en\/"},{"@type":"ListItem","position":2,"name":"Service","item":"https:\/\/www.ofenfeinstaubfilter.de\/en\/service\/"},{"@type":"ListItem","position":3,"name":"Installation"}]},{"@type":"WebSite","@id":"https:\/\/www.ofenfeinstaubfilter.de\/en\/#website","url":"https:\/\/www.ofenfeinstaubfilter.de\/en\/","name":"OFENFEINSTAUBFILTER","description":"by BERTRAMS + BLUEFIRE + CULIMETA","publisher":{"@id":"https:\/\/www.ofenfeinstaubfilter.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.ofenfeinstaubfilter.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.ofenfeinstaubfilter.de\/en\/#organization","name":"OFENFEINSTAUBFILTER","url":"https:\/\/www.ofenfeinstaubfilter.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.ofenfeinstaubfilter.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.ofenfeinstaubfilter.de\/wp-content\/uploads\/2025\/10\/Ofenfeinstaubfilter_Logo_blau.webp","contentUrl":"https:\/\/www.ofenfeinstaubfilter.de\/wp-content\/uploads\/2025\/10\/Ofenfeinstaubfilter_Logo_blau.webp","width":1920,"height":308,"caption":"OFENFEINSTAUBFILTER"},"image":{"@id":"https:\/\/www.ofenfeinstaubfilter.de\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.ofenfeinstaubfilter.de\/en\/wp-json\/wp\/v2\/pages\/1714","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ofenfeinstaubfilter.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ofenfeinstaubfilter.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ofenfeinstaubfilter.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ofenfeinstaubfilter.de\/en\/wp-json\/wp\/v2\/comments?post=1714"}],"version-history":[{"count":10,"href":"https:\/\/www.ofenfeinstaubfilter.de\/en\/wp-json\/wp\/v2\/pages\/1714\/revisions"}],"predecessor-version":[{"id":2062,"href":"https:\/\/www.ofenfeinstaubfilter.de\/en\/wp-json\/wp\/v2\/pages\/1714\/revisions\/2062"}],"up":[{"embeddable":true,"href":"https:\/\/www.ofenfeinstaubfilter.de\/en\/wp-json\/wp\/v2\/pages\/1696"}],"wp:attachment":[{"href":"https:\/\/www.ofenfeinstaubfilter.de\/en\/wp-json\/wp\/v2\/media?parent=1714"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}